Condition monitoring detects WHIMS bearing damage at 4 RPM

Online condition monitoring using SPM HD detected developing thrust bearing damage on a Wet High-Intensity Magnetic Separator (WHIMS) operating at approximately 4 RPM. The early indications helped support planned bearing maintenance at a mineral processing plant.

Application and monitoring setup

Thirteen WHIMS units were equipped with Intellinova Parallel EN systems and DuoTech accelerometers in August and September 2024. The systems monitor thrust bearings using SPM HD and HD ENV measurements.

Results and benefits

Indications of bearing damage were visible in the first measurements in September 2024. A sharp increase in measurement values in April 2025 prompted the bearing to be replaced.

By summer 2025, the system had detected four bearing faults, enabling the customer to complete four planned bearing replacements across the thirteen monitored separators, reducing the risk of costly breakdowns and secondary damage.